Sign In | Join Free | My ccnmag.com
China Beijing Silk Road Enterprise Management Services Co.,LTD logo
Beijing Silk Road Enterprise Management Services Co.,LTD
People-oriented, good faith service, the pursuit of excellent quality.
Verified Supplier

6 Years

Home > Tower Internals >

Sectional Made Custom Design Flow Rate Trough Distributor

Beijing Silk Road Enterprise Management Services Co.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Sectional Made Custom Design Flow Rate Trough Distributor

  • 1
  • 2

Certification : ISO 9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiation

Payment Terms : L/C, T/T

Supply Ability : 99 units per month

Delivery Time : 3-5 days

Packaging Details : pallet, wooden box

Product : Trough Liquid Distributor

flow rate : as per requirement

Material : stainless steel, or as per order

type : gravity type

Plate thickness : 3 mm, 4 mm, 5 mm, 6 mm, etc.

Size : any size as per order

Position : On top of packing

Application : packing tower

Design service : yes

Advantage : uniform distribution

Contact Now

Trough Liquid Distributor sectional - made custom design flow rate

1. Trough liquid distributor introduction,

Liquid distributor is the most important column internal from a process point of view. It is required to distribute liquid uniformly at the top of packing tower. Meanwhile a liquid distributor must have sufficient gas passage area to avoid high pressure drop or liquid entrainment.

2. Choice of liquid distributor:

Column Diameter

mm

Specific liquid load

M3/m2*h

System fouling tendency Turndown ratio Suitable type of liquid distributor
250 - 900 0.75 - 5 Low - medium <10:1

Trough type liquid distributor with sump

Deck type liquid distributor with orifices on drip tubes

5 - 30 Low - medium 2:1

Pan type liquid distributor

Trough type liquid distributor with sump

>30 Low - medium 2:1

Pan type liquid distributor

Trough type liquid distributor with sump

Deck type liquid distributor

>900 0.75 - 5 Low - medium <10:1

Trough type liquid distributor with parting box

Deck type liquid distributor with orifices on drip tubes

5 - 30 Low - medium 2:1

Trough type liquid distributor with sump

Trough type liquid distributor with parting box

Deck type liquid distributor

>30 Low - medium 2:1

Deck type liquid distributor

Trough type liquid distributor with sump

3. Liquid distributors usage:

Column internals like liquid distributor play very important role in effective mass transfer performance. So they need to be designed carefully for both process and mechanical point. Meanwhile, the engineers put great effort into structured packing and random packing development in the recent years. The column internals include mist eliminators, feed pipes, distributors, re-distributors, support plates, bed limiters, collector trays, etc.

4. How to choose liquid distributor?

When we need to select a liquid distributor, we need to consider the tower diameter, flow rate, turndown ratio, available height (in case of revamp) and fouling resistance.

Weir type gravity distributor:

Generally speaking, the weir type gravity distributor is one of the least troublesome distributors. It has excellent trundown capability and can handle large liquid load. However it can usually provide only a limited number of drip points (minimum 30 number of weirs per m2). It is also extremely sensitive to levelness and liquid surface agitation.

Orifice type gravity distributor:

Usually it shows as pan type, deck type or tunnel (trough) type. An orifice pan distributor consists of a pan. There are circular or rectangular risers for vapor flow and perforation for liquid flow in the pan.

Orifice trough type distributors consist of parallel troughs with perforated holes in the bottom for liquid flow. Vapor rises in the space between the troughs. The troughs are often interconnected by cross channels (called as parting box), which help equalize the liquid level in different troughs. This trough type liquid distributors provide more open area for vapor flow and is easier to support.

Orifice type distributor can be designed to have a large number of drip points to provide superior liquid distribution, though it may suffer from corrosion and plugging. Orifices are sized to maintain a minimum liquid head at desired turndown conditions & to avoid distributor overflow during turn up condition. Very small orifice diameters (<4mm) are avoided to prevent fouling.

5. Trough liquid distributor production

Sectional Made Custom Design Flow Rate Trough Distributor

Welcome your contact with your private tower internals plan or ideas!


Product Tags:

custom design flow rate trough distributor

      

sectional made custom trough distributor

      

sectional custom made trough distributor

      
China Sectional Made Custom Design Flow Rate Trough Distributor wholesale

Sectional Made Custom Design Flow Rate Trough Distributor Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Silk Road Enterprise Management Services Co.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)